All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an…
All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
Exploit Weaponization & PoC Radar
IT-Admin-Dringlichkeit · Forscher-Angriffsfläche · Exploit-Belege
Hersteller-Sicherheitsmeldungen & Patch-Status
Hersteller-Bulletins · Patches · Verifizierte Primärquellen
Es liegt ein offizielles Hersteller- oder Sicherheits-Advisory vor, jedoch ist noch keine finale Fix-Version verifiziert. Prüfen Sie das verlinkte Advisory auf Updates oder Workarounds.
CWE-Schwachstellen-Taxonomie & Defensive Architektur
Schwachstellen-Klassen · Root Cause · Mitigation
Cyber Threat Intelligence & Forensik
ATT&CK-Navigator · IoC-Radar & Graph
Compliance, SLA & Vendor Adherence
CVSS-Vektor · Score-Einordnung · Behörden-Triage