cve: "CVE-2025-13845"
severity: "HIGH"
cvss: 8.4
epss: "32%"
vendor: "Schneider Electric"
kev: false
exploited: false
published: "2026-01-15 19:16:02"
tags: [cve, security, high]
source: tsecurity.de CVE-Dossier
exported: "2026-09-16T18:21:30+02:00"
---

# CVE-2025-13845

> 8.4 HIGH

## Beschreibung

CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody.

## CVSS-Vektor

```
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
```

| Metrik | Wert | Bewertung |
|---|---|---|
| AV Angriffsvektor | Lokal | good |
| AC Komplexität | Gering | bad |
| PR Privilegien | Keine | bad |

## Schwachstellen-Klasse

- **CWE-416** — Use After Free
  The product reuses or references memory after it has been freed. At some point afterward, the memory may be allocated again and saved in another pointer, while the original pointer references a location somewhere within the new allocation. Any operations using the original pointer are no longer valid because the memory "belongs" to the code that operates on the new pointer.

## Referenzen

- <https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-04.pdf>

---
_Exportiert aus dem [tsecurity.de CVE-Dossier](https://tsecurity.de/cve?cve=CVE-2025-13845) · Datenquellen: EUVD (ENISA), NVD, OSV, CISA KEV, FIRST EPSS, Exploit-DB, BSI BITS_