Zero-Day & Vulnerability Intelligence Hub
Echtzeit-Tracking mit EPSS Exploit-Wahrscheinlichkeiten, Angriffsvektor-Decodern und KI-Patch-Anleitungen.
📊 Historien-Charts — Criticals-Trend · Vendors · EPSS-Verteilung
| Tier | CVEs | Anteil | Δ 7 T |
|---|---|---|---|
| ≥90 % | 792 | 0,2 % | +5 |
| ≥50 % | 3.560 | 0,9 % | +2 |
| ≥10 % | 13.173 | 3,2 % | +12 |
| <10 % | 397.050 | 95,8 % | +993 |
🗂️ …
CVE-2023-49231 | An authentication bypass vulnerability was found in Stilog Visual Planning 8. It allows an unauthenticated attacker to receive an administrative API token.
An authentication bypass vulnerability was found in Stilog Visual Planning 8. It allows an unauthenticated attacker to receive an administrative API token.
CVE-2023-30909 | A remote authentication bypass issue exists in some OneView APIs.
A remote authentication bypass issue exists in some OneView APIs.
CVE-2023-20900 | A malicious actor that has been granted Guest Operation Privileges https://docs.vmware.com/en/VMware-vSphere/8.0/vsphere-security/GUID-6A952214-0E5E-4CCF-9D2A-90948FF643EC.html in a target virtual machine may be able to elevate their privileges if that target virtual machine has been assigned a more privileged Guest Alias https://vdc-download.vmware.com/vmwb-repository/dcr-public/d1902b0e-d479-46bf-8ac9-cee0e31e8ec0/07ce8dbd-db48-4261-9b8f-c6d3ad8ba472/vim
A malicious actor that has been granted Guest Operation Privileges https://docs.vmware.com/en/VMware-vSphere/8.0/vsphere-security/GUID-6A952214-0E5E-4CCF-9D2A-90948FF643EC.html in a target virtual machine may be able to elevate their priv
CVE-2023-2846 | Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series main modules allows a remote unauthenticated attacker to cancel the password/keyword setting and login to the affected products by sending specially crafted packets.
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series main modules allows a remote unauthenticated attacker to cancel the password/keyword setting and login to the affected products by s
CVE-2022-45789 | A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers B
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Exp
CVE-2022-43704 | The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the tar
The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing
CVE-2022-41541 | TP-Link AX10v1 V1_211117 allows attackers to execute a replay attack by using a previously transmitted encrypted authentication message and valid authentication token. Attackers are able to login to the web application as an admin user.
TP-Link AX10v1 V1_211117 allows attackers to execute a replay attack by using a previously transmitted encrypted authentication message and valid authentication token. Attackers are able to login to the web application as an admin user.
CVE-2022-42731 | mfa/FIDO2.py in django-mfa2 before 2.5.1 and 2.6.x before 2.6.1 allows a replay attack that could be used to register another device for a user. The device registration challenge is not invalidated after usage.
mfa/FIDO2.py in django-mfa2 before 2.5.1 and 2.6.x before 2.6.1 allows a replay attack that could be used to register another device for a user. The device registration challenge is not invalidated after usage.
CVE-2022-29593 | relay_cgi.cgi on Dingtian DT-R002 2CH relay devices with firmware 3.1.276A allows an attacker to replay HTTP post requests without the need for authentication or a valid signed/authorized request.
relay_cgi.cgi on Dingtian DT-R002 2CH relay devices with firmware 3.1.276A allows an attacker to replay HTTP post requests without the need for authentication or a valid signed/authorized request.
CVE-2022-29878 | A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices use a limited range for challenges that are sent during the unencrypted challenge-response communication. An unauthenticated attacker could capture a valid challenge-response pair generated by a legitimate user, and request the webpage repeatedly to wait for the same challenge to reappear for which the correct response is known. This could allow the attacker to access the m
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices use a limited range for challenges that are sent during the unencrypted challenge-response communication. An unauthenticated attacker could capture a val
CVE-2021-38459 | The data of a network capture of the initial handshake phase can be used to authenticate at a SYSDBA level. If a specific .exe is not restarted often, it is possible to access the needed handshake packets between admin/client connections. Using the SYSDBA permission, an attacker can change user passwords or delete the database.
The data of a network capture of the initial handshake phase can be used to authenticate at a SYSDBA level. If a specific .exe is not restarted often, it is possible to access the needed handshake packets between admin/client connections. U
CVE-2020-5300 | In Hydra (an OAuth2 Server and OpenID Certified™ OpenID Connect Provider written in Go), before version 1.4.0+oryOS.17, when using client authentication method 'private_key_jwt' [1], OpenId specification says the following about assertion `jti`: "A unique identifier for the token, which can be used to prevent reuse of the token. These tokens MUST only be used once, unless conditions for reuse were negotiated between the parties". Hydra does not check the uniqu
In Hydra (an OAuth2 Server and OpenID Certified™ OpenID Connect Provider written in Go), before version 1.4.0+oryOS.17, when using client authentication method 'private_key_jwt' [1], OpenId specification says the following about assertion `
CVE-2020-5261 | Saml2 Authentication services for ASP.NET (NuGet package Sustainsys.Saml2) greater than 2.0.0, and less than version 2.5.0 has a faulty implementation of Token Replay Detection. Token Replay Detection is an important defence in depth measure for Single Sign On solutions. The 2.5.0 version is patched. Note that version 1.0.1 is not affected. It has a correct Token Replay Implementation and is safe to use. Saml2 Authentication services for ASP.NET (NuGet package
Saml2 Authentication services for ASP.NET (NuGet package Sustainsys.Saml2) greater than 2.0.0, and less than version 2.5.0 has a faulty implementation of Token Replay Detection. Token Replay Detection is an important defence in depth measur
CVE-2018-7790 | An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If
CVE-2017-6034 | An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the follo